Product Description
This cable has been designed for long haul duct / backbone application, it is a
Non-Metallic construction cable, its stranded loose tube design provides stable
performance over a wide temperature range and is compatible with any telecommunications-
grade optical fiber. Duct type Fiber Optical Cables are designed for easy and economical
installation.
The stranded loose tubes contain thixotropic jelly but the cable core is based on
dry-block construction. Incorporation of Dry Water Block Technology eliminates the
need for traditional jelly filled water blocking methods, thus providing efficient
and craft-friendly cable installation.
The thixotropic jelly is used to fill the buffer tubes to prevent water ingress.
Length markings in meters for easy determination of cable length. Extra Strength
cable can also be delivered with Peripheral Strength Members.
Features & Application
- Excellent optical, mechanical & environmental performance
- High strength-to-weight ratio
- CSM dielectric type – Fiber Reinforced Plastic
- Dry block construction
- High tensile strength
- High crush strength
- Corrosion resistance
- KINK resistance
- Very light weight
- Very flexible & small bending radius
- Long haul / backbone application
- Junction communication systems
- All dielectric applications
- CATV applications
|
|
|
|
Cable Construction Detail
|
|
 |
|
Construction Parameters |
|
Fiber Count |
216 Fiber |
|
Max. no. of Loose Tube |
18 |
|
No. of Fiber in each Tube |
12 |
Color of Fiber in each Tube |
Blue , Orange , Green , Brown , Grey , White , Red , Black, Yellow , Purple , Pink
& Aqua |
|
Loose Tube Material |
Polybutylene Terephthalate (PBT) |
|
Loose Tube Filling Material |
Thixotropic Jelly |
|
Filler Material (if required) |
Medium Density/High Density Polyethylene (MDPE/HDPE) |
Central Strength Member |
Fiber/Glass Reinforced Plastic (FRP/GRP) |
|
Core Moisture Protection Methodology |
Dry Block Design, Water Blocking Yarns/Tapes |
|
Peripheral Strength Member (if required) |
Aramid / Glass Yarn |
|
Sheath Material |
High Density Polyethylene (HDPE) |
|
Printing on Outer Sheath |
Engraved Hot Foil or Inkjet Printing |
|
Nominal Cable Delivery Length (km) |
2 KM + 3% |
|
|
Mechanical Characteristics |
|
Tensile Strength (N) |
2,700 |
|
Crush Strength (N) |
2,500 |
|
Minimum Bending Radius (mm) |
10 x outer diameter of Cable without load
20 x outer diameter of Cable with load |
|
Temperature Operating Range |
-20 to +70°C |
|
Water Penetration |
24 Hours |
|
|
|
Optical Characteristics |
|
Fiber Color Coding |
As per TIA/EIA-598A |
|
Fiber Type |
Single Mode G.652.D |
|
Mode Field Diameter, µm |
8.6 to 9.5 ± 0.7 |
|
Cladding Diameter, µm |
125 ± 1 |
|
Core Clad concentricity error (µm) |
< 1.0 |
|
Clad Non-circulatory % |
< 2 % |
|
Chromatic Dispersion, ps/ (nm.km) |
< 3.5 at 1310
< 18 at 1550 |
|
Polarized Mode Dispersion ps/√km |
< 0.20 |
|
Cut-off Wavelength, nm |
< 1260 |
|
Cabled Attenuation @ 1310 nm (dB/km) |
0.35 (average) |
|
Cabled Attenuation @ 1550 nm (dB/km) |
0.21 (average) |
|
Attenuation Uniformity at 1310 nm & 1550 nm (dB/km) |
No point greater than 0.05 dB at both 1310 & 1550 nm |
|
|
Note: Available in Composite (i.e. G.655.C + G.652.D) constructions also. |
|
|
| |
|
|